Set the thermostat or the device's controller Gas Control Trade Replacement Valve | Resideo Pro The recalled valves were manufactured between Now, turn the temperature control knob to the Very Hot position right off the bat. Status light blinking 1 more time indicates a specific part of the unit is not working properly. So, the control board issued a High Temperature Shutoff error code and caused the gas valve to shut down which stopped the gas supply to the pilot light and extinguished the pilot flame. However we have provided information below to try and help you resolve your water heater problem. When the pilot flame was extinguished, the thermopile, which sits next to the pilot flame, was no longer enveloped by the flame, which the thermopile relies upon to produce the electricity to operate the control board in the gas valve. [emailprotected]. Shank Length - (NG) for Sure Comfort Water Heaters Compare Model# SP10963D Rheem PROTECH 3/4 in. Once you locate the leak you can either replace the fittings, or install a new valve to solve the problem. Often blamed on sediment in the tank, the 4 flashes is one of the most common problems with the Honeywell gas valve. The air intake is located on the bottom or side of the water heater and may need to be cleaned out in order for the pilot to stay lit. Turn off the unit by setting the gas valve to the off position. The handle of the valve should be parallel to the pipe. The purpose If you get this code and have lukewarm water and the pilot is still on, try turning up the temperature. Next, check the condensate drain. Cool Air Mechanical refunded Mike for the part, but what about the labor cost? Attorneys working with ClassAction.org have reason to believe the plastic temperature sensor, which is inserted into the water heater and gauges how warm the water is, contains a defect that allows a pin-sized hole to form. Now, you can turn the temperature control knob to your desired setting, and you will hear the water heater burner ignite. Note: The instructions on my water heater indicate to wait 5 or 10 minutes, after the knob is in the OFF position, before lighting the pilot. Free shipping on orders over $99 Gas Control Valve Kit (LP Gas) Brand: AO Smith. Thats important to note because when you get to step 3, below, you should see 4 flashes on the LED status light after you light the pilot light. The water heaters have a nameplate near the Emerson gas control valve with the following model number ranges. The label displays the date code by year and week of manufacture. Water Heater Leak Lawsuits | Thermostat Problems Turn the temperature control knob to the OFF position. So, if you have 4 flashes at the LED status light, like I did, follow the steps below to fix the problem. Honeywell Wv8840b1110 As you continuously keep pressing the igniter button, you can find the status light blinks 4 times every three seconds. SKU: 100112338 (8) In Stock. Heater Pilot Light Wont Light. If not, then it is turned off. Finally, turn the temp knob to your desired temperature setting. VIEW REPLACEMENT. If the pilot remains lit you will need to replace the gas control valve. WebWASHINGTON, D.C. (Jan. 15) -- The U.S. Consumer Product Safety Commission announced the recall of more than 200,000 gas control valves used in heating Although, its unclear exactly how many water heaters have the problem, and where they were all installed. What do plumbers charge for the repair? Water heater not working? Now, you have a working water heater. WebAnyway my water heater stopped working and I have not been able to get my status light on the Honeywell GV/Thermostat to come back on using the common trick on youtube and trying to relight. 4330 East-West Highway Bethesda, MD 20814, Contact Us: 800-638-2772 (TTY 800-638-8270) If the tube gets restricted, you must clean it so that condensation can easily drain through it. Ensure you detach everything that leads into the gas control valve. Water Heater Igniter Wont Spark The recall pertains to combination gas control valves which bear one of the following model numbers and were used in LP fueled heating appliances: Consumers should exercise caution when attempting to locate the valve and its model number which is located on the side of the gas valve. I did see that. Before replacing the burner, I highly recommend you to clean the burner. Have the model number and serial number of the water heater ready. The steps should not take you more than 5 minutes to complete. So, now, lets get on to the simple and quick steps you take to resolve the problem. Gas Control Valve Kit (Natural Gas) Brand: AO Smith. That is why we want to be sure you are aware of an important safety notice. Once the company received the Rheem credit, they should have deducted it off the customers bill. When a claim is made, Rheem sends the new valve directly to the customer. WASHINGTON, D.C. (Jan. 15) -- The U.S. Consumer Product Safety Commission announced the recall of more than 200,000 gas control valves used in heating appliances fueled by LP (Liquid Propane) gas because they may create an explosion hazard. Attorneys working with ClassAction.org have reason to believe the Honeywell thermostat that comes standard on certain brands of water heaters is The assembly includes the pilot tube. If not, just turn the main gas control valve counterclockwise to let the gas flow. Lets talk about the error codes, or flashes, to help you understand what the flashes tell us. Go along with the following steps to fix this blinking issue: The status light on Honeywell Gas Valve makes a 4-consecutive flash every 3 seconds due to a failed temperature sensor. The valve controls temperature, but it also ignites the pilot light. WebEnergy. In this article, what I am going to cover: The status light on a water heater means either the unit is operating normally or its malfunctioning. Gas valves returned to Honeywell as the result of leakage complaints were tested as follows. water heater CPSC has been informed of 28 explosion incidents involving LP fueled appliances which have occurred since February 1972, in which Honeywell valves, which are a component in an overall furnace system, were present. Another important thing to mention before you follow the steps below. Add a comment any time and describe the water heater gas control valve and other features for best possible resources. Often blamed on sediment in the tank the 4 flashes is one of the most common problems with the honeywell gas valve. The first is the air intake, water heater build after 2004 have a sealed combustion chamber and air is not as easily drawn in as older models. What you need to do now is- compare the resistance output with the expected resistance at different temperatures mentioned in the manual. And the purpose of this blog is to help others. If the control board doesnt work, your water heart wont work. How to reset the Honeywell Gas Water Heater? The recalled fireworks are overloaded with pyrotechnics intended to produce an audible effect, violating the federal regulatory standards for this product. Actually, it depends on how many times the status light is blinking. How to Seal Caulking Tubes with Candle Wax, Honeywell Gas Valve 4 Flash EASY Fix (With Photos). The problem was the Honeywell gas valve control board had failed. CPSC's work to ensure the safety of consumer products has contributed to a decline in the rate of injuries associated with consumer products over the past 50 years. WebThe gas valve on the gas supply pipe may be shut off. Recall: Models of R110 Series Gas Control Valves - CSA Group 10. WebThe WT8840 water heater control from Resideo is designed for use in standing pilot applications using an immersion well for water temperature sensing. Keep in mind; you wont find the status light to blink if the unit goes into the High Temperature Shutdown status. Pulling it apart and putting it back together sometimes does the trick. To test the thermopile voltage, pull out the bottom access cover from the unit. If you have a Honeywell gas valve on your water heater, and you find you have no hot water, this may be the answer to your problem and the easy fix. The Honeywell gas valve went into High Temperature Shutdown mode. When this happens, the gas valve closes, extinguishes the pilot light and your water heater stops heating water. More options available. The labor is not warrantied, a Cool Air Mechanical employee said in a conversation Mike recorded. If the first two digits are 00, 01, 02, 03, 04, 05, 06, the electric baseboard heater thermostat is included in the safety recall. But, your burner will NOT ignite and heat the water until you override, or reset, the 4 flash error code. I have a Reliance brand, 40 gallon, natural gas water heater with a Honeywell gas valve, model WV8840B1109, and it has this common problem. Attorneys The Commission is seeking complaint and incident data concerning gas control valves and encourages consumers to report this information to the U.S. Consumer Product Safety Commission's toll-free hot line at 800-638-2772. For further assistance you may contact Robertshaw at (888) 225-1071 between 8 a.m. and 8 p.m. Were here to answer your questions and help you get started right away. When you see the 4 flashes at the LED status light, immediately turn the temperature control knob to the VERY HOT position. I did not see that one, the employee responded. How to Tell If a Honeywell Gas Valve Is Bad | Hunker There are several reasons this valve may stop working properly. The model and serial number can be found on the manufacturers label on the water heater. We are working on it. The combination valves serve the dual purpose of regulating the gas supplied to the appliance and of shutting off the gas supply when the pilot light is extinguished. Honeywell Water Heater Gas Control Valve Recall T10 Pro Smart Thermostat with RedLINK Room Sensor, Control comfort, air quality and your budget. They are: Fortunately, I broke down these three culprits in this article on Rheem Water Heater 8 Flashes Then 1. Then, clean the burner by blowing away every speck of dirt. Likely though, if your water heater has gone into High Temperature Shutdown status, you wont see any flashes on the LED status light. I did see that, the employee admitted. If the Status light blinks two times consecutively every 3 seconds, its because of either low thermopile voltage or you forget to turn on the main valve. On the other hand, know the water heater is not working properly if the status light is blinking two or more times every 3 seconds. Call CPSCs Hotline at 800-638-2772 (TTY 301-595-7054). Honeywell Water Heater valve problems WV8860C1008 Guy's, I have a newer water heater $ Rheem 40 gallon 38,000 BTU Ultra Low NOx model number This is a picture of a test to verify the gas valve had the proper working pressure. How Do I Reset My Honeywell Gas Water Heater? Obrien is one of hundreds, perhaps thousands, of Rheem customers who bought new water heaters with defective gas control valves. To locate the valve, consumers may have to remove the access panel on the front of their heating appliance. Recognized in the U.S., Canada and around the world, CSAs marks appear on over one billion products worldwide. A models require a transformer not used in B models. A quick note before we get to the steps to fix the problem. The status light on Honeywell Gas Valve makes a 4-consecutive flash every 3 seconds due to a failed temperature sensor. Function: The gas valve is a low voltage control (usually 24 VAC) that allow gas into the combustion chamber. They have a manual shut off. Please do not return these products to retail stores. What Does the Status Light Mean on A Water Heater? As I mentioned earlier, status light blinking 1 time every 3 seconds is normal. I'll show you how to troubleshoot and diagnose the problem with your water heater and Honeywell gas valve. But, if your water heater does go into High Temperature Shutdown again, you will know how to override and reset the error code and fix it yourself. Honeywell voluntarily initiated the gas valve recall in March 1980, and have contacted LP gas suppliers nationwide, who in turn have contacted LP gas users. Fu San Machinery Recalls Low Lead Ball Valves Installed in Flammable Gas Lines Due to Fire and Explosion Hazards, Fisher Controls International, Inc. On my particular Honeywell gas valve, model WV8840B1109, the error codes indicate the following: 4 High Temperature Shutdown, 5 Temperature Sensor Failure, 7 Gas Control or Valve Failure.